Tel:+86-825-7880081
The 10A Molecular Sieve is a calcium and sodium type of aluminosilicate. The pore size of the molecular sieve is 8nm, which could absorb any molecules smaller than the pore size.
Item | Unit | Sphere | |
Size | mm | 1.0~1.6 | 3~5 |
Static H2O Adsorption (RH50%,25℃) | % | ≥28 | ≥28 |
Wear Rate | % | ≤0.3 | ≤0.2 |
LOI(575℃,3h) | % | ≤1.5 | ≤1.5 |
Radial Crush Strength | N/piece | ≥15 | ≥70 |
Static Hexane Adsorption | mg/g | ≥18 | ≥18 |
Flour Yield | NTU | ≤30 | ≤30 |
Elimination of water: According to the regeneration of gas pressure, temperature, water content to develop a regeneration scheme.
Under the normal circumstance, a temperature of 200 ~ 350℃is required. Regeneration gas at 0.03 ~ 0.05Mpa through the molecular sieve bed (3 ~ 4h), and then make sure the outlet temperature is 110 ~ 180℃, finally, cooling.
Removing organic: water vapor take the place of organic, and then remove water vapor.